Close loop analysis of a single phase high-efficiency AC-DC CUK converter with low input current THD and improved power factor
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Institute of Electrical and Electronics Engineers Inc.
Abstract
In this paper, design and analysis of a novel single phase AC-DC converter based on ĆUk topology is proposed. Performance comparisons are shown between open loop and closed loop configurations of the proposed converter which reveals that the inconsistencies arising in open loop connection can be mitigated sufficiently by adding PFC controller to it. The closed loop technique applied to the proposed bridgeless converter results in low input current THD at input AC mains along with near unity (0.99) power factor. Thus, significant improvements in overall power quality of the system is achieved despite the absence of input side filtering. The proposed circuit is also non-burdensome as it gets rid of bulky filtering capacitors. The aforementioned circuit performances are observed based on software simulations using PSIM 9.1 professional environment.
Description
Keywords
Citation
Akter, K., Sarowar, G., & Ahmed, S. F. B. (2018, December). Close loop analysis of a single phase high-efficiency AC-DC CUK converter with low input current THD and improved power factor. In 2018 10th International Conference on Electrical and Computer Engineering (ICECE) (pp. 393-396). IEEE.